Note: If the charger is equipped with options C1 and C2, following these instructions involves doing wiring changes to the charger, only a trained electrician is allowed to do these.

Step-by-step guide

There is 2 different “permanently locked plug” -features in 5.X firmware version:

  1. Is settable from web UI 2.0  with operator user rights. Is intended to be used/managed by end user or backend operator locally or remotely via web UI or mobile app in private (or semi-private as renting park slot for some tempararely period). The user itself can decide when the plug is set or un-set as permanent locked. In that mode lock is still under control of controller board and the power outage will open the lock as there might be situation that user wants to release plug during power outage.

Image Added


  1. Is settable only in old web UI (URL with legacy word) Manufacturer user rights. Is intended to be used/managed by electrician locally on site for public chargers. The electrician decides when the plug is set (or un-set) as permanent locked. The operator/user cannot override that parameter (once set by manufacturer page then the operator cannot set or unset feature 1. lock). In that mode lock is not opening on the power outage situation.

Image Added


In old firmware version fixed charging cable must be set active with USB-memory stick: 

...